The Texas Circuit | November 2026

Having trouble viewing this email? View it as a Web page.

The Texas Circuit

November 2026


State of the State

Texas and U.S. Flags

For this month’s “State of the State” we are discussing our latest licensing reciprocity updates. Texas House Bill 11 became law on September 1, 2025. This bill states that TDLR “shall maximize licensing reciprocity agreements, with respect to licenses issued by the department, to the extent allowed by law.” Since September of 2025, we have added five master electrician agreements and one journeyman electrician agreement with various states.

The current reciprocal agreements we have for Master Electrician are with Alabama, Arkansas, Iowa (Class A master electrician), Louisiana (state contractor’s license), Nebraska, North Carolina (master electrician or unlimited electrical contractor), Ohio, and Tennessee (Electrical Contractor).

Current list of reciprocal agreements we have for Journeyman Electrician are with Alabama, Alaska, Arkansas, Idaho, Iowa, Nebraska, New Mexico, Oklahoma, South Dakota and Wyoming.

To qualify for reciprocity in Texas for journeyman, an out-of-state applicant must have held their license in good standing for at least one year and qualified for their license by taking said state’s administered exam. To qualify for reciprocity for a master, the out-of-state applicant requirements are the same as above, plus proof of having held a journeyman license. We hope to add many more reciprocity agreements as we continue to talk to other states.


Code Article of the Month

For this month’s code article we are featuring the new 2026 NEC requirement in 120.41 for dwelling unit feeder and service load calculations.

November code article of the month image

 

As you see pictured above, this change to 2 va per square ft. is for one-family, two-family, and multifamily dwelling unit feeder and service minimum unit loads. A common misconception is that it reduces the general circuit calculation for dwellings in 120.13 requiring 3 va per square ft. when calculating the minimum number of general lighting circuits required in the dwelling to 2 va as well. But it does not. The general circuit calculation for dwellings in 120.13 is still 3 va per square ft. With newer lighting products increasing efficiency in dwellings, the drop to 2 va from 3 for feeder and service unit loads was justified. This can have an effect on the dwelling unit service size but still keep the number of general circuits required by square ft. the same.


Closing the Circuit

electrical safety equipment

In closing, if there are any questions on reciprocity and you are unsure if you qualify for any of our agreements contact me at josh.hall@tdlr.texas.gov and I can walk you through the requirements. Although we might not have an agreement with a state you previously or currently worked or have worked in, we can still accept your hours performing electrical work in that state if there is a master or equivalent in that state that will sign off on your hours on our Texas application. However, the exam would not be waived if there is no agreement with that state. See y’all next month!


Have questions, comments or suggestions? Contact Chief electrical inspector Larry Reichle and Deputy Chief Josh Hall at Larry.reichle@tdlr.texas.gov and Josh.hall@tdlr.Texas.gov.